¡¡¡¡BKE's cable accessories
use the state-of-the-art technologies
developed in America, and only the imported
raw material to achieve product superiority.
To the best of our knowledge, BKE's
cable accessories line is the only product
in China that takes the full advantage
of the manufacturing processes used
in USA. Our USA-partner transfers the
methodologies to BKE. We produce the
inside semi-conductive coat, the insulating
coat, the outside semi-conductive coat
of the cable accessories by the one-time
injection module methodology. |
|
¡¡¡¡
¡¡¡¡According
to the structure, including accessories
that are in accordance with ANSI/IEE386
standards and DIN47636 standards.
¡¡¡¡According to the fixing style, including
drawing-inserting cable connector and
bolt-fixing cable connector.
¡¡¡¡According to the current ratings,
including 200A series and 630A series.
¡¡¡¡According to the voltage ratings,
including 15kV and 25Kv series.
|
|
¡¡¡¡
630A
Loadbreak Junction
|
|
|
¡¡¡¡The
630A deadbreak junctions are
installed in junction enclosures.
They have the bus bars to provide
complete insulation and are
permanently sealed. The
deadbreak junctions are used to branch
circuits. There are three types
of junctions.
¡¡¡¡Depending on the number of
branches, they are 2-position
Junction, 3-position Junction
and 4-position Junction. The
rated current is 630A.
|
|
630A/200A
Deadbreak Transfer Junction
|
|
|
¡¡¡¡This type
of Deadbreak Junction is a pattern
pending product. The rated current
for the input is 630A. Input
can be connected with T- OP
Deadbreak connector or T-II
Deadbreak connector. The output
of the junction is 200A. The
output can be connected to an
elbow connector, arrester and
200A insulated protective cap.
|
|
200A
Loadbreak Elbow Connector
|
|
|
¡¡¡¡It
can be used on 10kV high-voltage
underground cable connecting
equipment, such as pad-mounted
and cable junction enclosure.
It can be used to connect cables
of sizes ranging 30-120 mm2
. The male probe can quench
arch can quench
arch, so it can be used as loadbreak
device to disconnect 200A circuit.
A test point cap or an elbow
fault indicator can be added
to an elbow for instant fault
detection and indication.
|
|
T-
OP Deadbreak Connector
|
|
|
¡¡¡¡It
can be used on 10kV high-voltage
underground cable connecting
equipment, such as pad-mounted
switch and cable junction enclosure.
It can be used to connect to
cables of sizes ranging 35-500
mm2 cables. A test point cap
or an elbow fault indicator
can be added to an elbow for
instant fault detection and
indication. The rated current
is 630A.
|
|
T-II
Deadbreak Connector
|
|
|
¡¡¡¡It
can be used on 10kV high-voltage
underground cable connecting
equipment, such as pad-mounted
switch and cable junction enclosure.
It can be used to connect
cables of sizes ranging 35-500
mm2 cables. A test point cap
or an elbow fault indicator
can be added to an elbow for
instant fault detection and
indication. The rated current
is 630A.
|
|
630A
Insulated Protective Cap
|
|
|
¡¡¡¡It
provides insulating protection
for the 630A deadbreak junction
and bushing. The rated current
is 630A.
|
|
200A
Insulated Protective Cap
|
|
|
¡¡¡¡It provides
insulating protection for the
630A deadbreak
junction and
bushing. The rated current is
200A
|
|
Loadbreak
Bushing Insert
|
|
|
¡¡¡¡It
can be used with the Loadbreak
Reducing Tap Plug (LRTP) in
cable junction enclosure or
transformer to reduce the 630A
connector to 200A plug.
|
|
Rotatable
Feedthru Insert
|
|
|
¡¡¡¡It can be
used with Loadbreak Reducing
Tap Plug (LRTP) in cable junction
enclosure or transformer to
reduce the 630A connector into
200A plug.
|
|
Loadbreak
Reducing Tap Plug (LRTP)
|
|
|
¡¡¡¡Connecting
to the Loadbreak Feedthru Insert
or Rotatable Bushing Insert,
a LRTP reduces 630A connector
into 200A circuit.
|
|
Loadbreak
Transfer Connector
|
|
|
¡¡¡¡Used
in cable junction enclosure
or pad- mounted switch, a
Deadbreak
Transfer Connector transforms
630A connector into 200A plug.
|
|
Bushing
Extender
|
|
|
¡¡¡¡Used
in cable junction enclosure
or pad- mounted switch, a Bushing
Extension connects 630A equipment
bushing or loadbreak junction
to 200A plug.
|
|
Connecting
Plug
|
|
|
¡¡¡¡Used
in cable branching network to
connect two T- OP Deadbreak
Connector,
functioning as a bus bar.
|
|
M.O.V
Elbow Arrestor
|
|
|
¡¡¡¡Used
in the cable branching network
to prevent over-current and
/ or over-voltage due to lightening.
|
|
Insulating
(Blocking) Cap
|
|
|
¡¡¡¡Used
with the T-body as an insulation
device.
|
|
Grounding
Cable Plug
|
|
|
¡¡¡¡Used
as a ground connection.
|
|
Circuit
Indicator
|
|
|
¡¡¡¡Connected
to the test point of an elbow
to see if the circuit is energized
or not. If a circuit is energized,
the indicting light will blink.
|
|
Clamp
Stick
|
|
¡¡¡¡Used
to install or pull off a loadbreak
elbow, bushing insert, arrestor,
200A protective cap; can be
operated when a circuit is energized.
|
|
|
|
¡¡¡¡
¡¡¡¡
¡¡¡¡The cable connector
accessories are pre-molded rubber connectors
for use both the main and the branching
distribution networks with pad-mounted,
cable Junction enclosure and transformers.
These accessories are in compliance with
the DIN47636 standards. They can be used
to connect cables with sizes ranging from
35 to 500
. A test point cap or an elbow fault indicator
can be added to an elbow for instant fault
detection and indication.
|