¡¡¡¡BKE Electric Company manufactures the state-of-the-art Pad-mounted for 12kV electric distribution system. These switches can be integrated into a modern electric distribution network to provide loop power, isolate faulted area automatically and sectionalize cable lines. When equipped with FTU and communication devices, these switches can be controlled remotely by a Distribution Automation master station.

¡¡¡¡
¡¡¡¡¡¤Utilizing as the insulating and arch-extinction medium.
¡¡¡¡¡¤Utilizing 5 mm stainless steel tank for small volume, lightweight, short arch-extinction time, durable contacts and free from maintenance.
¡¡¡¡¡¤Equipped with view window to provide intuitive viewing of the cut-off point.
¡¡¡¡¡¤Both loadbreak and grounding switches are housed in a sealed casing and the terminals can be connected to separable cable accessories, conforming to all protection requirements.
¡¡¡¡¡¤The compartment is compact, small volume, easy to access, convenient for operation and free of maintenance.
¡¡¡¡¡¤Manual and motor operations are available options. Can be integrated into a Distribution Automation system by adding RTU/FTU.
¡¡¡¡¡¤Manually operated switches are upgradeable to motor (automatic) operated in system expansion.

¡¡¡¡
¡¡¡¡¡¤Utilizing as the insulating and arch-extinction medium.
¡¡¡¡¡¤Utilizing 5 mm stainless steel tank for small volume, lightweight, short arch-extinction time, durable contacts and free from maintenance.
¡¡¡¡¡¤Applying 3-phase integrated, compressed-air structure, reducing arch-extinction time and down time.
¡¡¡¡¡¤The main and grounding switches are independently operated, ensuring high service reliability and safe operation.
¡¡¡¡¡¤Every circuit breaker is independently protected by its own relay. Relay operations are triggered through the secondary current of the CT inside. Operators can modify the opening/closing criteria by adjusting the control on the panel based upon the TCC.
¡¡¡¡¡¤The protective circuits have back up batteries to prevent overcharge and discharge.
¡¡¡¡¡¤The compartment is compact, small volume, easy to access, convenient for operation and free of maintenance.
¡¡¡¡¡¤Each switch is equipped with motor operating mechanism to operate the circuit-breaker.
¡¡¡¡¡¤The control source of motor control box is 24 V, DC, through output PT. The DC source is obtained from converting an AC source. The configuration of the charging line is two-way input and one single way output. The two way input sources are interlocked to ensure the reliability of operation source.
¡¡¡¡¡¤Manually operated switches are upgradeable to motor (automatic) operated in system expansion.
¡¡¡¡¡¤Operating counts indicating opens/closes are can be viewed by the operator.

¡¡¡¡
¡¡¡¡¡¤Utilizing as the insulating and arch-extinction medium.
¡¡¡¡¡¤Utilizing 5 mm stainless steel tank for small volume, lightweight, short arch-extinction time, durable contacts and free from maintenance.
¡¡¡¡¡¤Applying 3-phase integrated, compressed-air structure, reducing arch-extinction time and down time.
¡¡¡¡¡¤The compartment is compact, small volume, easy to access, convenient for operation and free of maintenance.
¡¡¡¡¡¤Conforming to all protection requirements.
¡¡¡¡¡¤The operating device and fuse chamber are interlocked. When the door is opened, the close operation cannot be initiated, ensuring safe and reliable operation.

¡¡¡¡
Rated Voltage
12kV
Rated Current
630A
Rated Frequency
50Hz
Rated Breaking Current
630A
Rated Short-time Withstand Current
20/3s
Peak Withstand Current
50kA
Frequency Insulation Feature of Phase- to -phase and Phase-to-earth
42kV
Frequency Insulation Feature of Insulation Breaker
48kV
Impulse Insulation Feature of Phase- to -phase and Phase-to-earth
95kV
Impulse Insulation Feature of Insulation Breaker
110kV
Mechanical Operation Times
£¾5000
Operation Times In Full Load-break
£¾200
Rated Gas Pressure(20¡æ)
7PSI.G
Yearly Leakage Rate of
£¼0.1%

¡¡¡¡
Rated Voltage
12kV
Rated Current
630A
Rated Frequency
50Hz
Rated Short-time Withstand Current
20/4s
Rated BIL
75kV
AC Withstand Voltage (1min)
42/48kV
Rated Load-break Current
630A
Magnetic Current
21A
Cable-charging Current
25A
Closing-loop Breaking Current
630A
Breaking Current
20kA
Making Current
50kA
Mechanical Operation Times
10000
Operation Times In Full Load-break
2000
Rated Gas Pressure(20¡æ)
7PSI.G
Yearly Leakage Rate of
£¼0.1%

¡¡¡¡
Rated Voltage
12kV
Rated Frequency
50Hz
Peak BIL of Phase- to -phase and Phase-to-earth
75kV
Peak BIL of Insulation Breaker
85kV
AC Withstand Voltage of Phase- to -phase and Phase-to-earth
42kV
AC Withstand Voltage of Insulation Breaker
48kV
Load-break Switch Rated Current
630kA
Rated Short-time Withstand Current(2S)
20kA
Rated Peak Withstand Current
50kA
Rated Short-circuit Making Current
50kA
Rated Current Opening Times
£¾200
Grouding Switch Rated Short-time Withstand Current(2S)
20kA
Rated Peak Withstand Current
50kA
Rated Short-circuit Making Current
50kA
Fuse Rated Current
125A
Rated Breaking Current
31.5kA
Service Life
£¾5000
Protective Rate of Cable Connector
IP67
Rated Gas Pressure(20¡æ)
7PSI.G
Yearly Leakage Rate of
£¼0.1%

 